BMS and DC-DC equipment applications
Choose the relevant equipment guide and prepare a procurement brief.
VOLUXIN ENGINEERING REFERENCE
Published series, current, port, interface and envelope entries across 16 models.
Read the table below. On small screens, scroll horizontally to view every column. Download the CSV to edit a worksheet in your spreadsheet application.
| Model | Catalogue application | Series entry | Current entry | Charge/discharge ports | Communication entry | Dimensions L x W x T |
|---|---|---|---|---|---|---|
| BF24-MND3 | 24V pedestrian warehouse vehicles | 7-8S | 35A discharge; 12A charge | Separate charge/discharge ports | CAN (isolated) | 160 x 60 x 12 mm |
| BF24-MNS3 | 24V pedestrian warehouse vehicles | 7-8S | 30A; charge/discharge duty not separated | Common charge/discharge port | CAN (isolated) | 170 x 60 x 12 mm |
| BF24-MNS5 | 24V pedestrian warehouse vehicles | 7-8S | 100A; charge/discharge duty not separated | Common charge/discharge port | CAN, 485/UART (isolated); configuration to confirm | 150 x 99 x 20 mm |
| BF24-RPS1 | 24V pedestrian warehouse vehicles | 7-8S | 150A; charge/discharge duty not separated | Common charge/discharge port | CAN (isolated) | 166 x 74 x 25 mm |
| BF24-RPX3 | 24V pedestrian and ride-on warehouse vehicles | 7-8S | 250A discharge; 150A charge | Common/separate port options; confirm configuration | CAN (isolated) | 166 x 74 x 25 mm |
| BF48-MND2 | 48V pedestrian warehouse vehicles | 13-16S | 30A; charge/discharge duty not separated | Separate charge/discharge ports | CAN (isolated) | 160 x 60 x 12 mm |
| BF48-MND3 | 48V pedestrian warehouse vehicles | 13-16S | 30A; charge/discharge duty not separated | Separate charge/discharge ports | CAN (isolated) | 160 x 60 x 12 mm |
| BF48-MNS5 | 48V pedestrian warehouse vehicles | 13-16S | 100A; charge/discharge duty not separated | Common charge/discharge port | CAN, 485/UART (isolated); configuration to confirm | 150 x 99 x 20 mm |
| BF48-RPX1 | 48V pedestrian warehouse vehicles | 15-16S | 150A; charge/discharge duty not separated | Common/separate port options; confirm configuration | CAN (isolated) | 178 x 80 x 26 mm |
| B16NS1-X | 24V/48V pedestrian warehouse vehicles | 7-16S | 40A; charge/discharge duty not separated | Common charge/discharge port | CAN/485 (isolated); protocol and option to confirm | 160 x 60 x 12 mm |
| B112A | 24V ride-on warehouse vehicles; 36V ride-on floor scrubbers | 7-12S | 250A; charge/discharge duty not separated | Common/separate port options; confirm configuration | Two CAN channels, 4G, Bluetooth; configuration to confirm | 193 x 102 x 30 mm |
| B136A | 48V ride-on warehouse vehicles; 80V counterbalance vehicles | 15-25S | 400A; charge/discharge duty not separated | Common/separate port options; confirm configuration | Two CAN channels, 4G, Bluetooth; configuration to confirm | 278 x 105 x 30 mm |
| BM72-MPS1 | 72V electric motorcycles | 17-20S | 50A; charge/discharge duty not separated | Common charge/discharge port | CAN, 485; configuration to confirm | 155 x 78 x 24 mm |
| B16MPX1 | 24V/36V/48V electric bicycles | 7-16S | 25A discharge; 10A charge | Common/separate port options; confirm configuration | CAN, 485, UART, single-wire; configuration to confirm | 60 x 40 x 15 mm |
| BV72-RPX1 | Special-purpose vehicles | 17-20S | 150A; charge/discharge duty not separated | Common charge/discharge port | CAN/485 (isolated); protocol and option to confirm | 155 x 78 x 24 mm |
| BA48-MNS11 | AGV | 13S or 15S (discrete options, not 14S) | 50A; charge/discharge duty not separated | Separate charge/discharge ports | CAN/485 (isolated); protocol and option to confirm | 174 x 60 x 16 mm |
VOLUXIN | Rev 1 | 2026-10-02 | Catalogue / procurement reference; final configuration and operating conditions require project approval.
A custom battery management system brief defines the battery, equipment duty and controller interface together. Use the topics below to request an OEM configuration review; available functions are agreed for the proposed design.
| Discussion topic | What to specify |
|---|---|
| Monitoring and protection | Specify cell voltage, pack current, temperature channels and required fault responses. |
| Balancing strategy | Compare balancing needs with pack size, charge time and thermal constraints. |
| SOC and communication | Define state-of-charge reporting, CAN or RS485 messages and controller responsibilities. |
| Mechanical integration | Identify separate or common current paths, connectors, mounting and enclosure requirements. |
A higher current rating is useful only with a defined duty cycle and heat-removal path. Select the pack and communication requirements before comparing catalogue models.
Industry reading: TI battery-system design requirements. Source documents inform the review topics; their product ratings, certifications and capabilities are not VOLUXIN specifications.
Catalogue references and blank worksheets support project discussions. They are not configuration-specific engineering specifications or completed test records.
CONTINUE YOUR ENGINEERING REVIEW
Follow the relevant guide for your procurement scope. A related link does not establish approved compatibility between a component and equipment.
Choose the relevant equipment guide and prepare a procurement brief.
Explore catalogue references and configuration questions.
Compare construction and published voltage-platform information.
Define bare-board fabrication and inspection requirements.