How to Size a DC-DC Converter for Auxiliary Loads

Size a DC-DC converter for auxiliary loads by listing the required output voltage and simultaneous loads, then checking startup demand, the full input voltage window and thermal conditions. A nominal battery voltage and a power label alone are not enough to confirm a suitable converter.

Build a load budget

List each load, its required voltage and current or power, and whether it operates at the same time as the others. Include controllers, sensors, lighting and other equipment only where they are actually part of the project. Record unknown values rather than guessing.

For a simple single-output example, two loads drawing 2 A and 3 A simultaneously at 24 V require 120 W of continuous output power: 24 V × (2 A + 3 A). This is an arithmetic illustration, not a product recommendation. Check the actual voltage tolerance, load profile and design margin for the application.

Worked load budget: continuous and startup

The following values are invented for calculation only. They are not measured data or VOLUXIN product ratings. Assume both loads share one 24 V output and operate simultaneously. The controller draws 2 A continuously. Another auxiliary load draws 3 A continuously and 8 A for a 0.5-second startup.

Continuous output is 24 × (2 + 3) = 120 W. If their startup currents coincide, the hypothetical instantaneous output demand is 24 × (2 + 8) = 240 W for 0.5 seconds. The example assumes a steady 24 V and does not model voltage sag or inrush waveform. Neither 120 W nor 240 W alone establishes a converter selection. Obtain actual waveforms and confirm output current limit, startup behaviour, peak duration, repetition and thermal conditions. If startup overlaps differ, calculate each credible operating scenario separately.

Check startup and changing loads

A motor, capacitor bank or other load may draw more during startup than during normal operation. Record the peak, its duration and repetition. Ask how the proposed converter responds to the actual load step and whether its output remains within the equipment’s limits. Analog Devices demonstrates load-step response for a specific converter design; its results cannot be transferred to a different product without evidence.

Define the real input window

Provide minimum and maximum operating voltage, nominal voltage and known transient conditions separately. A platform label does not replace the actual input range of the selected variant. Check output voltage options against the load: a listed 14 V or 27.5 V output should not automatically be treated as interchangeable with a generic 12 V or 24 V requirement.

Estimate input current for the operating point

At a stated operating point, input power is approximately output power divided by efficiency. For illustration only, 120 W output at an assumed 90% efficiency requires approximately 133 W input; at a steady 48 V input this is about 2.8 A. Efficiency and input voltage vary, and this estimate excludes startup and transients. The assumed efficiency is not a VOLUXIN specification. Check input current, cable voltage drop, fuse and upstream source limits using the actual converter documentation and worst relevant conditions.

Review heat and installation

Rated output can depend on cooling, mounting and ambient conditions. Provide installation space, airflow, enclosure, expected temperature and operating duty. Review derating and startup behaviour against the exact configuration’s documentation. Output power and input power differ because the converter has losses; efficiency varies with operating conditions. Texas Instruments’ TPS82130 datasheet illustrates how current derating for that device depends on operating and thermal conditions. It does not specify a VOLUXIN converter.

Confirm the rest of the specification

Discuss isolation and grounding needs, enable control, connectors, ripple, fault behaviour, electromagnetic compatibility and mechanical fit. Requirements should come from the equipment design and applicable project standards; do not assume every converter offers every feature.

For the broader selection process, read Specifying a DC-DC Converter for Auxiliary Loads. This article focuses on building a load budget and evaluating startup scenarios. Use the VOLUXIN DC-DC catalogue to identify a starting range and the engineering library for the load review worksheet. Discuss the completed brief through custom engineering support. VOLUXIN confirms available options and suitability for the proposed configuration.

Frequently asked questions

Is the sum of continuous load power enough to size a converter?

No. Review credible simultaneous startup demands, input range, output tolerance and thermal derating as well as continuous power.

Does a 24 V system always require exactly 24 V output?

The equipment’s permitted input range decides. Confirm the converter’s actual output, tolerances and voltage drop at the load; do not assume a 27.5 V option is compatible.