Power electronics for equipment manufacturers & integratorsinfo@voluxin.com+86 15957148220
Request a Quote ↗

VOLUXIN · POWER & BATTERY MANAGEMENT

Specifying a DC-DC Converter for Auxiliary Loads

BMS and DC-DC component supply for equipment manufacturers and integrators.

72V DC-DC Module Range — DC-DC catalogue reference
800V DC-DC Converter Range — DC-DC catalogue reference

POWER & BATTERY MANAGEMENT

Specifying a DC-DC Converter for Auxiliary Loads

Published by VOLUXIN · Updated 30 September 2026. General selection guidance; the agreed configuration-specific documents govern an order.

Specify a DC-DC converter from the source voltage window and the loads it must supply. Then review construction, operating conditions and control behaviour for the exact configuration. A family name such as 72V or 800V is not the complete input specification.

1. Check the complete input window

Write down the lowest and highest expected steady-state supply values over the operating cycle. Identify transient conditions separately so they can be checked against a relevant specification. A published steady-state range should not be treated as a transient rating.

The 72V converter range states 50–100V input. As an illustrative range check, a proposed 55–95V steady-state supply sits inside those limits; a proposed 45–95V supply does not. Passing the range check alone says nothing about thermal, isolation, transient or output suitability.

2. Use the actual output value

Record the voltage and tolerance allowed by each load. Catalogue options include 14V and 27.5V; they must not automatically be described as 12V and 24V outputs. Compare the stated value with the load specification rather than choosing a familiar system label.

Some family exceptions matter. The 800V enclosed series includes a 51V output option whose input entry is 400–750V, unlike the 500–950V range of its main options. The 350V catalogue lists 70V for a module option and 72V for an enclosed option. Keep those values distinct.

3. Make a load budget

Illustrative load at an assumed 24V output Running current Calculated running power
Controller 2A 48W
Sensors 1A 24W
Lighting 3A 72W
Simultaneous total 6A 144W

This calculation uses P = V × I and is an example, not a VOLUXIN product rating or a recommendation for a 27.5V output. The 144W total excludes start-up, peaks, losses and any agreed design allowance. List the duration and coincidence of temporary loads separately. Input power also depends on efficiency; do not assume an unpublished efficiency value.

4. Separate rated power from operating capability

Ask for the continuous output capability at your ambient temperature, mounting and cooling conditions, plus any derating information. A catalogue rated-power entry alone does not validate the operating cycle. Document overload and start-up requirements so they can be reviewed for the selected option.

5. Confirm construction and control

Choose the module or enclosed construction around the intended installation. Specify isolation and environmental requirements separately. The catalogue mentions power-up output, KL15 hardwire control and combined KL15/CAN control options; confirm their availability and the required behaviour for the exact ordering configuration.

Common questions

Can I select solely by the battery nominal voltage?

No. Use both input limits across the operating cycle, and identify transients separately. Nominal platform names are a way to organise the catalogue, not the full acceptance criteria.

Is a 1kW catalogue option guaranteed to supply 1kW continuously in my enclosure?

Not without the applicable temperature, cooling and duty conditions. Request the configuration-specific specification and evaluation plan.

What should I include with the model code?

Include input platform and range, actual output, required power/current, construction and wake/control option. Reused catalogue labels are not complete ordering codes by themselves.

Download the requirements worksheet (CSV)

Browse DC-DC modules and converters, review industrial auxiliary-power applications or prepare the enquiry brief.

VOLUXIN ENGINEERING REFERENCES

Compare products and prepare your technical brief

Read catalogue comparison tables and procurement worksheets online, or download an editable CSV. Reference tables reproduce published entries; worksheets are blank review aids, not test results or final engineering specifications.

ReferencePurpose
DC-DC configuration referencePlatform, construction and exact model/output rows; repeated labels remain attached to their range.
DC-DC load review worksheetSource window, auxiliary loads, cooling and evaluation conditions.

VOLUXIN editorial references · Worksheets updated 5 October 2026; catalogue reference tables dated 2 October 2026. BMS/DC-DC values are based on supplied product catalogues; PCB entries use the 2026 fabrication reference. Request configuration-specific drawings, protocols and evaluation records for the quoted scope.

Tell us what your equipment needs.

Share your application, product requirements and any details you have already confirmed. We can then discuss the available options.

Discuss Your Requirements